Double-beam system atomic absorption and emission with RS 232

FOB Reference Price:Get Latest Price
$7,000.00 - $9,300.00 / Set | 1 Set/Sets (Min. Order)
Measurement Range:
190-900nm
Shipping:
Support Sea freight
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Henan, China
Brand Name:
Nanbei
Model Number:
AA320N
Bandwidth:
0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
Wavelength accuracy:
≤ ±0.5nm
Wavelength Repetitiveness:
≤ 0.3nm (single direction)
Standby Interface:
RS 232
Wavelength Range:
190-900nm
Supply Ability
Supply Ability:
10000 Set/Sets per Month
Packaging & Delivery
Packaging Details
Export standard packaging
Port
Qingdao/Tianjin/Shanghai
Product Description

Double-beam system atomic absorption and emission   with RS 232 

Characteristics A

1 Buildin computer data processing and LCD: adopting highly integrated micro digital circuit, which is stable and reliable with the functions of integral holding, peak height and area, auto zero adjusting, deuterium lamp and background, multilinear and nonlinear curves fitting, various parameters and working curves displayed in screen and report printing, etc. It is equipped with interface for externally linking PC.

 

2Good basic line stability: Double-beam system of optimized design can automatically compensate the light 

s ource drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability. The cathode lamp needs not be preheated for long time and sample can be analyzed immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.

 

3 High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration

 

4Optical path of high energy: A total reflection system is adopted to eliminate color difference in full range. By means of chemical conversion, a round light spot of the light source becomes a long light spot, which enters into the slit. Therefore the light flux of double beam is enhanced.   

 

5 Long-life and anti-corrosive atomization system: The burner is made of new type titanium alloys, anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling.

 

6 Multifunctional analysis mode: for methods of flame absorption, flame emission, graphite furnace atomic absorption and hydride generation.

 

7 Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame .

 

8 Complete set of accessories: to be supplied with the instrument and ready for use after they are purchased.

 

Characteristics B

 

1 Lightsource system: Hollow cathode lamp power supply: with adjustable current Deuterium Lamp power supply: with fixed current

 

2 Optical system: Double beam total refection system, C-T type monochromator Flashing wavelength: 250nm

 

3 Flame atomization system: Interchangeable titanium alloy burner of 10cm and 5cm slits. Gas path is equipped with pressure indication, high precision voltage stabilizing flow adjustment, fast conversion of air and nitrous oxide, gas supply cut off, power cut off, prevention of flashback and logic interlock protection devices.

 

4 Signal processing: absorptance, concentration, emission and emission concentration; Standard curves: linear regression, curve fitting and multipoint standard calibration. Average value, standard deviation, relative standard deviation and correlation coefficient can be worked out. Standard curves, atomic absorption peak diagram, spectrum outline sketch, data as well as instrument parameters list and analytical reports can be displayed and printed out.

Specifications:

 

1 Working spectral range: 190-900nm

2 Wavelength accuracy: ≤ ±0.5nm

3 Wavelength repeatability: ≤ 0.3nm (single direction)

4 Spectrum bandwidth: 0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm

5 Resolution: <40%

6 Base line stability: ±0.004Abs/30min

7 Characteristic concentration of copper: ≤ 0.04mg/ml/1%

8 Detection limit of copper: ≤0.008mg/ml

9 Background calibration ability: Greater than 30 times.

10 Standby Interface: RS 232 

11 Instrument power supply: 220V, 3A, 50Hz

The host picture:

 

Accessory

Main accessories supplied with the instrument: Several decades of accessories including air compressor, one piece of Cu hollow cathode lamp. Gas external pipe, acetylene cylinder pressure-reducing valve and water knockout gas filter.

 

Optional accessories:

1 GA3202 HGA graphite furnace system: Used to conduct trace and ultratrace analysis with an absolute sensitivity of 10-10-10-12 gram.

 

2 5cm long-life titanium burner: The necessary accessory for nitrous oxide-acetylene flame analysis.

 

3Hydride generator (Totally automatic): Making the characteristic concentration of As, Se, Sb, Bi, Pb, Sn, Te, Ge, In, Tl, C

d and Zn lower than ppb level with cold atomic mercury measurement method.

 

4 Hollow cathode lamp: All specifications are available.

 

Graphite tube: All specifications are available.

 

6 Software with I/O port

 

7 Printer

 

The graphite furnace system:

 

 

Warranty:

1 Our technical staff could come to install and provide the training 

2 Our products have the warranty of 1 year, if anything wrong with the products, you could contact us freely, we will provide the most satisfied service for you